AX-9/S Specifications

DISPLAY 5-digit LED
MESSAGE CENTER 20 character alpha-numeric
METAL RANGE 0.1" - 10.0" nodular iron
ALARMS High/Low velocity
READOUT English or metric
COUPLANT DISTANCE RANGE 0.1" - 12.0"
MONITOR Power supply levels
SPEED <1 sec per test
OPERATION Manual/Full Auto
CIRCUITRY Digital/Solid State
CONTROL Microcomputer
ENCLOSURE NEMA-12
MODES Pulse-echo/Through transmission
MULTI-CHANNELED Up to 16 channels
OUTPUTS Std Microbus
COUPLANT VELOCITY COMPENSATION Automatic
FREQUENCY 1.0 - 25.0 MHz
GAIN Manual or AGC
SIGNAL LEVEL MONITORING Automatic
NOISE IMMUNIZATION Unique discrimination
SHIFT REGISTER For use in automatic sorting
TEST METHODS Bubbler/Immersion
TESTING STATUS Stationary or Moving part
CALIBRATION Minimum operator requirement
OPERATING TIME 24-7 in foundry conditions
OSCILLOSCOPE Tektronix
CIRCUITS Plug-In cards
BATTERY BACKUP 5 years
SELF DIAGNOSTICS Standard
DATA ENTRY 20 position keyboard
AUX PANEL Optional